extech

Extech PQ3470: 3-Phase Graphical Power & Harmonics Analyzer/Datalogger

Download       

       00961 1 894 243

Description

Datalogging Power Analyzer (up to 30,000 sets of measurements)

The PQ3470 is a 3-phase graphical power and harmonics analyzer/data logger capable of logging up to 30,000 sets of measurements on a removable SD memory card. The meter features a 3-phase voltage or current unbalanced ratio (VUR, AUR) and unbalanced factor, captures transient events (including dip, swell, and outage) with programmable threshold (%), a wide sampling rate range (2 seconds to 2 hours), a built in clock/ calendar and a CAT III 600 Volt safety rating. Complete with one year warranty, 4 voltage leads with alligator clips, 8 AA batteries, SD card, 100-240 Volt AC adaptor and case. Clamp probes sold separately.

  • Large dot-matrix, sun-readable, numerical, backlit LCD with easy-to-use onscreen menu|Full system analysis with up to 35 parameters:
    • V (phase-to-phase), V (phase-to-ground)
    • A (phase-to-ground)
    • KW / KVA / KVAR / PF (phase)
    • KW / KVA / KVAR / PF (system)|
    • KWH / KVAH / KVARH / PFH (system)
    • Phase angle
  • Optional 200A, 1200A Current Clamps or 3000A Flexible Current Probes (sold separately)|Adjustable Current Transformer CT (1 to 600) and Potential Transformer PT (1 to 1000) ratio for high power distribution systems
  • Simultaneous display of Harmonics and Waveform|Analysis of Total Harmonic Distortion (THD)
  • Graphic Phase diagram with 3-Phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, AUR) and unbalanced factor
  • Capture Transient events (including dip, swell, and outage) with programmable threshold (%)
  • Log up to 30,000 reading on a removable SD memory card in Microsoft Excel® format
  • Wide sampling rate range (2 seconds to 2 hours)
  • Built-in Clock and Calendar
  • Complete with 4 voltage leads with alligator clips, 8 AA batteries, SD card, 100-240V AC adaptor and case. Clamp probes sold separately.

Specifications:

Specifications Range Basic Accuracy
AC Voltage (True rms) 600.0V ±(0.5%rdg)
AC Current 3000A ±(0.5%rdg)
Active Power (MW) 9.999MW ±(1.0%rdg)
Apparent Power (MVA) 9.999MVA ±(1.0%rdg)
Reactive Power (MVAR) 9.999MVAR ±(1.0%rdg)
Power Factor 0.00 to 1.00 ±0.04
Frequency Range 45Hz to 65Hz ±0.1Hz
Phase -180° to +180.0° ±1°
Harmonics 1 to 50th ±2% (1 to 20); ±4% (21 to 31)
Crest Factor 1.00 to 99.99 ±(5%)
Current Clamp input 200mV, 300mV, 500mV ±(0.5%rdg)
1V, 2V, 3V; user-selectable
Peak AC Voltage Accuracy ±(5%)
Peak AC Current Accuracy ±(5%)
Active Power Energy (MWH) 0.0kWh to 9.999MWH ±(2.0%rdg)
Apparent Power Energy (MVAH) 0.0KVAh to 9.999MVAH ±(2.0%rdg)
Reactive Power Energy (MVARH) 0.0kVARh to 9.999MVARH ±(2.0%rdg)
Datalogging 30,000 readings (2GB SD memory Card)
Dimensions/Weight 8.86 x 4.92 x 2.52″ (225 x 125 x 64mm) / 2.2lbs (1010g)

Additional information

Labels