External Filter Housing
Clear External filter housing allows an
immediate visual inspection of filter’s condition.
Flow Fault & Test Indicators

Flow Fault indicator lights up if unit
operates outside ± 5% of set flow rate. Battery Test indicator lights up when battery can provide a minimum of 8 hours of operation over operating range.
Basic, Clock, & Program Models

Basic model is easy to use. Clock model
provides elapsed-time clock display. Program model provides auto start-stop and delayed start times up to 9999 mins.
Optional Low Flow Modules

Constant Low Flow module allows
sampling from 20-500 cc/min. Constant Pressure (Multiflow) Module allows sampling from 1-750 cc/min.

Product Specifications:
PERFORMANCE

Flow Range
……………………….………. 1- 5000 cc/min (Total),
                                                                 850 – 5000 cc/min (High Flow);

                                                                 20-500 cc/min (Constant Low Flow);

                                                                 1-750 cc/min (Constant Pressure)

Constant Flow Control
………………….. ± 5% of set flow at 1000-5000 cc/min
Flow Compensation
……………………… 5000cc up to 8” H20 back pressure
                                                                    4000cc up to 18” H20 back pressure

                                                                    3000cc up to 23” H20 back pressure

                                                                    850cc up to 29” H20 back pressure

Run Time
……………………………………. 8 hour minimum
Flow Fault
…………………………………… If flow changes exceed 5%, fault icon
                                                                    appears. If fault exceeds 30 seconds,

                                                                    pump shuts down. Pump attempts to

                                                                    restart every 3 minutes for up to 1 hour

ENVIRONMENTAL

Temperature Ranges

Operating 
…………………………………….. 32°F to 104°F (0°C to 40°C)
Storage
………………………………………… -49°F to 113°F (-45°C to 45°C)
Charging
………………………………………. 41°F to 104°F (5°C to 40°C)
Humidity Ranges

Operating
………………………………………… 0-85 %RH, non-condensing
Storage
……………………………………………. 0-100 %RH, non-condensing
GENERAL

Display Messages
……………………………… LAST, CAL, SHUT/OFF (Clock,
                                                                          Program); E, PC, P1-P6, OLD

                                                                          (Program)

Controls
………………………………………….. Power Switch, Flow Control Screw &
                                                                         Buttons (Clock, Program),

                                                                         Programming (PROG) Button

                                                                         (Program)

Indicators
………………………………………… Elapsed Time (Clock, Program)
Icons (LCD)
……………………………………… Low Battery, Flow Fault, Clock
                                                                          (Clock & Program)

Dimensions
………………………………………. 3.9W x 4.1H x 2.0D inches
                                                                           10.0W x 9.0H x 5.1D cm

Weight
……………………………………………… 22.5 oz. (638 g)
ELECTRICAL

Battery Pack
………………………………………. NiMH
Interface Connectors
…………………………… Charging Jack
Charging Time
……………………………………. 14-18 hours
APPROVALS/PERFORMANCE

Intrinsic Safety – UL

Class 1, Div 1, Groups A, B, C, D;

Class 2, E, F, G; Class 3

EMC: Emissions Standards

EN 55011:2009/A1:2010 Group 1, ClassA

ICES-003 – Issue 2 Class A

FCC PArt 15 (per ANSI C63.4:2015) Class A Verification

EMI: Immunity Standards

EN 61326-1:2013;

IEC 61000-4-2:2006 / EN 61000-4-2:2009;

IEC 61000-4-3:2006 / EN 61000-4-3:2006/A1:2008/

A2:2010

Additional information