Meter

Meter TEROS 10: Soil Moisture Probe

Download     

       00961 1 894 243

Description

The new, ultra-robust TEROS 10 soil moisture sensor delivers scientific accuracy and reliability at a price that makes large sensor networks economically practical. TEROS 10 is designed to withstand some of the harshest field conditions, which means problem-free measurements over the longevity of your research. In fact, we’re so confident about the long life of our TEROS sensor line, we’ve increased our standard warranty from one to three years. Ideal for large sensing networks, it is sensitive to small VWC changes across
the entire range of soil and substrate water content and can be installed in anything from dry desert soils to very wet peat. Not
only that, the TEROS 10 has very low power consumption and a high resolution.

TEROS 10 eliminates common problems that cause uncertainty in the data—things like air gaps and preferential flow. How? The
TEROS 10 is compatible with the TEROS Borehole Installation Tool which mistake-proofs installation. Because of its mechanical advantage, the tool delivers consistent, flawless installation into any soil type (even hard clay) while minimizing site disturbance.
Sensors are installed straight in and perpendicular with no sideto-side movement, then gently released to prevent air gaps and preferential flow.

FEATURES:
– Low-cost, ruggedized soil moisture sensor
– Ideal for large sensor networks
– Sharpened stainless steel needles are securely fastened and reduce breakage
– Compatible with TEROS Borehole Installation Tool ensuring fast, errorfree installation with little site disturbance
– 3-year long-life guarantee
– Check installation or troubleshoot with the ZSC Bluetooth sensor interface
– Measure VWC in a harsh environment
– Robust epoxy body means it lasts for 10+ years in the field
– 430 mL volume of influence
– Repeatability can be checked with an accuracy verification standard
– Plug and play with METER data loggers
– Ferrite core eliminates cable noise
– Easy integration with third-party systems

Specifications:

MEASUREMENT SPECIFICATIONS
Volumetric water content (VWC)
Range:
Mineral soil calibration: 0.00–0.64 m3/m3
Soilless media calibration: 0.0–0.7 m3/m3
Apparent dielectric permittivity (εa): 1 (air) to 80 (water)
NOTE: The VWC range is dependent on the media the sensor is calibrated to. A custom calibration will accommodate the necessary ranges for most substrates.
Resolution: 0.001 m3/m3. Accuracy: Mineral soil
calibration: ±0.03 m3/m3 typical in mineral soils that have solution EC <8 dS/m
Soilless media calibration: ±0.05 m3/m3 typical in media that has a solution EC <8 dS/m
Medium specific calibration: ±0.01–0.02 m3/m3 in any porous medium
Apparent dielectric permittivity (εa): 1–40 (soil range) , ±1 εa (unitless) 40–80, 15% of measurement
Dielectric measurement frequency
70 MHz
COMMUNICATION SPECIFICATIONS
Output: 1,000 to 2,500 mV
Data logger compatibility
METER data loggers (ZL6, EM50/60 series) or any data acquisition systems capable of switched 3.0–15 VDC excitation and single-ended voltage measurement at greater than or equal to 12-bit resolution.
PHYSICAL SPECIFICATIONS
Dimensions
Length: 5.1 cm (2.02 in). Width: 2.4 cm (0.95 in)
Height: 7.5 cm (2.95 in)
Needle length 5.4 cm (2.11 in)
Cable length
5 m (standard). 40 m (maximum custom cable length)
NOTE: Contact Customer Support if a nonstandard cable length is needed.
Connector types
3.5-mm stereo plug connector or stripped and tinned wires
ELECTRICAL AND TIMING CHARACTERISTICS
Supply voltage (VIN to GND)
Minimum: 3.0 VDC. Typical: NA. Maximum: 15.0 VDC
Operating temperature range
Minimum: –40 °C. Typical: NA. Maximum: 60 °C
NOTE: Sensors may be used at higher temperatures under certain conditions; Contact Customer Support for assistance.
Measurement duration Minimum: 10 ms. Typical: NA. Maximum: NA
COMPLIANCE
Manufactured under ISO 9001:2015 EM ISO/IEC 17050:2010 (CE Mark) 2014/30/EU and 2011/65/EU EN61326-1:2013 and EN55022/CISPR 22

Additional information

Labels