FLUKE

Fluke 805: Vibration Meter

$2,332.00

Description

The Fluke 805 is not a vibration pen; it’s a meter. A Fluke meter that eliminates the confusion of vibration screening and provides reliable measurements you can trust to make critical go or no-go maintenance decisions.

Features and Benefits

  • Innovative sensor design helps minimize measurement variations caused by device angle or contact pressure
  • Consistent data quality at both low and high frequency ranges
  • Four-level scale indicates severity of problems for overall vibration and bearing condition
  • Exportable data via USB
  • Trending in Microsoft® Excel using built-in templates
  • Overall vibration measurement (10 Hz to 1,000 Hz) for acceleration, velocity and displacement units of measurement for a wide variety of machines
  • Crest Factor+ provides reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
  • Colored lighting system (green, red) and on-screen comments indicate how much pressure needs to be applied to take measurements
  • Temperature measurement with Infrared Temperature Sensor increases diagnostic capabilities
  • On-board memory holds up to 3,500 measurements
  • Audio output for listening to bearing tones directly
  • External accelerometer support for hard to reach locations
  • Flashlight for viewing measurement locations in dark areas
  • Large screen with high resolution for easy navigation and viewing

Use the 805 to check the following machine categories:

  • Chillers (refrigeration)
  • Fans
  • Cooling tower drives
  • Centrifugal pumps
  • Positive displacement pumps
  • Air compressors
  • Blowers
  • Generic gearboxes (rolling element bearings)
  • Machine tools (motor, gearboxes, spindles, etc.)

Specifications: Fluke 805 Vibration Meter

Vibration Meter
Low frequency range (overall measurement) 10 Hz to 1,000 Hz
High frequency range (CF+ measurement) 4,000 Hz to 20,000 Hz
Severity levels Good, satisfactory, unsatisfactory, unacceptable
Vibration limit 50 g peak (100 g peak-peak)
A/D converter 16-bit
Signal to noise ratio 80 dB
Sampling rate Low frequency 20,000 Hz
High frequency 80,000 Hz
Real time clock backup Coin battery
Sensor
Sensitivity 100 mV g ±10%
Measurement range 0.01 g to 50 g
Low frequency range (overall measurement) 10 Hz to 1,000 Hz
High frequency range 4,000 Hz to 20,000 Hz
Resolution 0.01 g
Accuracy At 100 Hz ±5% of measured value
Amplitude Units
Acceleration g, m/sec²
Velocity in/sec, mm/sec
Displacement mils, mm
Infrared Thermometer (Temperature Measurement)
Range -20°C to 200°C (-4°F to 392°F)
Accuracy ±2°C (4°F)
Focal length Fixed, at ~3.8 cm (1.5 in)
External sensor
Fluke supports but does not provide external sensors
Frequency range 10 Hz to 1,000 Hz
Bias voltage (to supply power) 20 VDC to 22 VDC
Bias current (to supply power) Maximum 5 mA
Firmware
External interfaces USB 2.0 (full speed) communication
Data capacity Database on internal flash memory
Upgrade Through USB
Memory Up to 3,500 measurements
Radiated Emission
Electrostatic discharge: burst Standard EN 61000-4-2
Electromagnetic interference Standard EN 61000-4-3
RE Standard CISPR 11, Class A
Environmental
Operating temperature -20°C to 50°C (-4°F to 122°F)
Storage temperature -30°C to 80°C (-22°F to 176°F)
Operating humidity 10% to 95% RH (non-condensing)
Operating/storage altitude Sea level to 3,048 meters (10,000 feet)
IP rating IP54
Vibration limit 500 g peak
Drop test 1 meter
General Specifications
Battery type AA (2) Lithium Iron Disulfide
Battery life 250 measurements
Size (L x W x H) 24.1 x 7.1 x 5.8 cm (9.5 x 2.8 x 2.3 in)
Weight 0.40 kg (0.89 lb)
Connectors USB mini-B 7-pin, stereo audio output jack (3.5 mm Audio Plug), external sensor jack (SMB connector)

Additional information

Labels